1) When using the Import Vertical from Surface the Station Lock has no impact on the locations of the extracted points, and this command operates as if the Station Lock were on, regardless of its actual position. (pg. 410)

2) There are no commands to remove a vertical alignment display from the CAD profile view (other than deleting the alignment itself within InRoads). If you viewed it with the Write Lock on and later didn’t wish to show it, you would either have to turn those CAD levels off or delete it with the CAD delete commands. (pg. 411)

3) If the Sight Distance is part of the desired Vertical Annotation on Curves, make sure that you establish the proper Eye Height and Target Height on the Sight Distance tab. (pg. 414)